Skip to main content

Independent. Diagnosis first, parts second.

+1 647-919-3041 [email protected]

Chromkit
Get a quote

Guides

Before you order

Most bad purchases in a chromatography lab are made confidently. These are the checks worth running first, written from methods I have actually had to fix.

Buying guide

What "equivalent" means when you buy an aftermarket part

A manufacturer asked me to write "alternative" instead of "equivalent" on their cross-reference table. They were right. Here is what a substitute part can honestly be promised, what it cannot, and the four things to ask for in writing.

Read →

Buying guide

Work out your lab's tariff exposure before 8 September

Canada's counter-tariff on US goods takes effect 8 September 2026. How to find the country of origin of your consumables, find the tariff item, and work out what changing supplier would cost you.

Read →

Primer

What every part in an HPLC does, and how it fails

A guide to the wear parts in an HPLC for anyone new to the instrument. Where each part sits, what it does, what you see when it goes bad, and which symptom points at which part.

Read →

Troubleshooting

Which lamp is failing in your UV-Vis spectrophotometer

A UV-Vis has two lamps, and the wavelength where the fault appears tells you which one to buy. Here is the changeover point, the test that costs nothing, and what to re-verify afterwards under USP <857>.

Read →

Buying guide

Who pays for the lamp when the instrument is under a service contract

Most service plans cover a lamp damaged by a repair, not a lamp that reaches end of life. Here is the distinction, what Agilent publishes about it, and the four questions to ask about your own agreement.

Read →

Troubleshooting

Fitting a lamp with no RFID chip, and what you have to do yourself

A chipless deuterium lamp gives 'UV lamp tag not ready' and will not ignite until you change one setting. Here is the setting, the lamp-hours step almost everyone forgets, and what it means in a GMP lab.

Read →

Troubleshooting

Pressure that will not settle: check valve, seal, or neither

Three parts get replaced on an unsteady HPLC pump, usually in the wrong order. Here is the free test that tells you whether a check valve is involved, when a seal is really the problem, and why a scored plunger makes you do the job twice.

Read →

Buying guide

Which lamp your Agilent detector takes, and why the system name does not tell you

A 1260 can take a 3-pin lamp or an 8-pin lamp, and they are not interchangeable. How to read the detector module number, and what G1314-60100, G1314-60101, 5182-1530, 2140-0820 and 5190-0917 actually fit.

Read →

Troubleshooting

Before you replace the deuterium lamp

A noisy baseline gets blamed on the lamp before anything else. Here is how a dying deuterium lamp actually behaves, the 3 checks that cost nothing, and what to confirm before you order one.

Read →

Troubleshooting

Your recovery is low, and it is probably not the instrument

A method that loses half its analyte is usually losing it during the extraction. Here is where it goes, and the experiments that tell you which one is happening.

Read →

Buying guide

Choosing a flash cartridge, and why most bad runs are decided before you start

Cartridge size, phase and loading are set by your TLC plate, not by what you have in stock. Here is how to pick, and the loading mistake that ruins more flash runs than any other.

Read →

Buying guide

Choosing a column for a polar analyte

A polar compound on a standard C18 elutes at the void and there is nothing to integrate. Here is how to pick the column before you buy the wrong one.

Read →

When a guide is not enough

The guides cover the failures I see most often. If you have read the one that matches your symptom and the method is still wrong, send it to me and I will look at yours properly. Your conditions, your chromatogram, a written diagnosis back.

Method audit

CA$300 · 5 working days